SE Series Hydraulic Shear Specification Table

Holddowns Gage Range Strokes (3)
Model Mild Steel Capacity (1) Length Between Housings Maximum Rake Force Tons Numbers Back Front (2) Max. Min. Motor
In./Ft. Per Minute Per Minute (HP)
4SE06 1/2" 6' - 3" 7/16" 16 9 48 47 31 17 40
4SE08 1/2" 8' - 3" 7/16" 19-1/2 11 48 47 30 14 40
4SE10 1/2" 10' - 3" 7/16" 23 13 48 50 30 12 40
4SE12 1/2" 12' - 3" 7/16" 26-1/2 15 48 54 30 11 40
4SE14 1/2" 14' - 3" 7/16" 30 17 48 59 29 10 40
4SE16 1/2" 16' - 3" 7/16" 33-12 19 60 64 29 9 40
4SE20 1/2" 20' - 3" 7/16" 40-1/2 23 60 65 28 7 40
6SE06 3/4" 6' - 3" 11/16" 28-1/2 9 48 48-7/8 25 11 50
6SE08 3/4" 8' - 3" 11/16" 35 11 48 48-7/8 25 10 50
6SE10 3/4" 10' - 3" 11/16" 41-1/2 13 48 48-7/8 24 8 50
6SE12 3/4" 12' - 3" 11/16" 47-1/2 15 48 52-7/8 24 7 50
6SE14 3/4" 14' - 3" 11/16" 54 17 48 58-7/8 24 6 50
6SE16 3/4" 16' - 3" 11/16" 60-1/2 19 60 58-7/8 23 6 50
6SE20 3/4" 20' - 3" 11/16" 73 23 60 64-7/8 22 5 50
8SE06 1" 6' - 3" 3/4" 39-1/2 9 48 62-1/4 16 7 50
8SE08 1" 8' - 3" 3/4" 48 11 48 62-1/4 15 6 50
8SE10 1" 10' - 3" 3/4" 57 13 48 62-1/4 15 5 50
8SE12 1" 12' - 3" 3/4" 65-1/2 15 48 65-1/4 15 4 50
8SE14 1" 14' - 3" 3/4" 74-1/2 17 48 68-1/4 14 4 50
8SE16 1" 16' - 3" 3/4" 83 19 60 72-1/4 14 3 50
8SE20 1" 20' - 3" 3/4" 100 23 60 76-1/4 14 3 50
  1. Refer to CINCINNATI Shear Capacity chart for equivalent capacity thickness based on specific grade of ASTM material.
  2. Front gage range based on use of optional front support arms.
  3. Speed is reduced to 5/6 when machine is equipped for 50 cycle service.

Due to a continuing development program, engineering date and dimensions are subject to change without notice. Certified foundation plans will be furnished for each installation.